#1. A building has 4 pedestrian entrances. How many of those entrances must be Barrier-Free entrances?
#2. An air-supported structure occupied by the public must be separated from other structures on the same property by a minimum of;
#3. Metal ties for multiple wythe masonry cavity walls are to be spaced at;
#4. If a guard is required in a house, what is the height of the zone which must not facilitate climbing?
#5. In a two storey residential building, the floor assembly to be 30-minute fire serration. What is the minimum required fire-resistance rating for the top storey of an exit stair shaft?
#6. 15.9 mm thick gypsum wall board attached to steel studs in an unrated partition with a stud spacing of 406 mm o.c. must be fastened with screws spaced at:
#7. service water heaters installed in Houses must be secured to the structure to resist overturning and displacement during an earthquake when:
#8. In accordance with Detail ED-1 in SB-7, what is the minimum deck joist size for this construction detail?
#9. In an open floor area, the travel distance to an exit is measured:
#10. According to table 9.8.7.1, if a curved stair is 1000 mm in width within a dwelling unit, the required hand rail to be:
#11. Panel-type roof sheathing to be placed with the face grain orientation:
#12. in a post and beam construction system, most repetitive structural members are spaced more than 610 mm apart. Consequently, they would need to be designed in conformance with:
#13. The minimum thickness of plywood cladding (face grain parallel to studs at 400 mm o.c) applied over sheathing is
#14. An exit opens directly into a lobby in an apartment building. The floor is unsprinklered, the lobby is enclosed with a fire separation having a 1hourfire resistance rating. The lobby is 1 m above the ground level and the distance of travel from the exits to the outdoors is 15 m and a suite door opens into a vestibule which in turn opens into the lobby
#15. An aircraft hanger has an occupant load of 10 people. What is the area which would support this occupant load?
#16. An exit stair is determined to be a minimum of 1 100 mm wide because of the occupant load it is expected to serve but a 1 500 mm wide stair is provided. This stair is also required to have a handrail on both sides. If both handrails project into the stair width, what is the maximum projection permitted?
#17. The double hung windows of a House have a pane area of approximately 0.39 m2. If the House was to be constructed in Goderich, the minimum thickness of the factory-sealed insulated glass (IG) units would be:
#18. Plywood panels used as cladding, when applied directly to studs spaced at 610 mm o.c. must not be less than:
#19. in a Division B Part 9 house, if the space between roof joists in a cathedral ceiling with a slope of 1 in 3 are installed, the ratio of vent area to insulated ceiling area to be provided shall be not less than:
#20. Except when a building is designed to accommodate accumulation of water at the building, a building shall be site graded so that surface water:
#21. A 1 800 mm opening in a 305 mm thick interior masonry wall and supporting 10 000 N of floor loading is required to have a steel lintel of comprising:
#22. A proposed new house to be built in Mississauga, window wall ratio is 19%. Electric forced air furnace is used to heat the house. C4 package. The windows would require a thermal conductance, U-value of:
#23. Is the foundation wall considered as lateral supported at bottom?
#24. A washroom containing plumbing fixtures for restaurant employees shall be located in;
#25. Where the finished flooring consists of other than matched wood strips or ceramic tiles, what is the minimum thickness of plywood subflooring applied over floor joists spaced at 610 mm o.c.?
#26. The minimum length of nails for the attachment of metal siding is:
#27. What would be the most economical (smallest size of stud with widest spacing) steel stud size and spacing for an interior non-loadbearing wall 3.5 m high?
#28. A suite serves a business and personal services occupancy, has an area of 150 m2 and the distance to the nearest egress door is 30 m. How many egress doors are required?
#29. Waferboard or OSB subflooring must be installed with the direction of face orientation:
#30. An exit door serving a two-storey House:
#31. An unfinished attic with no occupancy has been insulated with spray foam insulation. The foam insulation have to be protected by:
#32. What is the minimum size of pickets in accordance with Detail ED-1 in SB-7?
#33. A roof, with Code complying asphalt fibreboard sheathing, may support the following type of roofing.
#34. A window is located in an exterior wall of a building adjacent to an unenclosed exit stair. This particular window is 4 500 mm above the stair and 3 500 mm away from the stair; this window;
#35. Glass for the bathtub enclosures on the second floor must be of the following type:
#36. An interior stair not serving a dwelling unit is required to have a landing(s) at the
#37. Any opening in an exterior non-loadbearing above-ground flat ICF wall must not occur within:
#38. A 4.76 mm by 40 mm carbon steel strip used to tie intersecting walls is required to have corrosion resistance which is in accordance with,
#39. Based on Division B, Article 9.10.1.4., if a commercial cooking equipment used in processes producing grease-laden vapours, the hood exhaust system to be designed and installed in conformance with Division B:
#40. In accordance with Detail ED-1 in SB-7, how many fasteners are required for each picket to the rim joist?
#41. In a flight of stair, treads and risers shall:
#42. An exterior window opening is required to have a steel lintel to support 90 mm wide brick veneer. When the span of the lintel is 3 000 mm what is the minimum size of the steel lintel?
#43. A wall in a building of residential occupancy that is located on a property line shall be constructed as a fire wall except:
#44. A house can contain maximum dwelling units of
#45. Assuming a two-storey building of residential occupancy, what is the minimum required fire-resistance rating for the top storey of an exit stair shaft?
#46. Collar ties may be assumed to provide intermediate support to roof rafters if the roof slope is:
#47. In calculating the actual unobstructed glass area provided by windows and skylights, the Designer and the Plans Examiner:
#48. within 600mm of the foundation wall and footing, a boulder with a diameter of:
#49. A suite serves a medium hazard industrial occupancy and has an area of 150 m2. How many egress doors are required and what is the maximum distance of travel to the nearest egress door?
#50. A semi-heated building located in Coolingwood that uses natural gas for space heating. The building is designed in accordance with the prescriptive requirements Division 3 of SB-10. What is the maximum U-value (in SI units) permitted for the roof where its isolation is located entirely above the deck?
#51. Consider Clause Article 9.10.19.3. Within a House, 4 bedrooms on second floor, ground floor and basement are open concept. There must be at least:
#52. What is the maximum wall height for an interior non-loadbearing wall built of 32 mm × 64 mm steel studs spaced at 610 mm o.c.?
#53. The minimum length of nails for the attachment of metal siding is:
#54. Closures for doors in a Barrier-Free path of travel and opening into entrances to normal dwelling units, must open with a force of not more than;
#55. An exterior exit door is located in an exterior wall at the main floor of a three storey office building. There is no internal enclosure to the exit stair and the main floor has a single tenancy (i.e., no public corridor). Adjacent to the exit door is a window which is 1 200 mm away from the door; this window;
#56. If we calculated the minimum width of the strip footing supporting the exterior walls of the House to be 480 mm if strip footings were to be constructed on gravel, sand or silt and the water table level was less than the width of the original footing below its underside elevation. The supported foundation wall is 200 mm in width. The minimum thickness of the strip footing widened by Clause 9.15.3.4.(3)(a) will be:
#57. If a landing is required, the minimum size of the exterior landing of an house main entrance door is:
#58. Wall assembly, with wood studs @ 406 mm o/c in a single row, using two layers of 15.9 mm Type X gypsum board on each side, with the loadbearing wall FRR 1.5h, nonloadbearing wall FRR 2h. STC 38. The proper wall number in SB-3 is:
#59. Automatic hand dryers for a lavatory in a Barrier-Free washroom are to be located;
#60. A three storey office building is required to have floors which are fire separations with a 1 h fire-resistance rating and a fire-resistance rating 30 minutes to the roof .What is the required fire-resistance rating for the fire separation of the exit stair shaft from the second to the third floor?
#61. The minimum thickness of particleboard placed on wall studs spaced at 400 mm o/c with mid height blocking is;
#62. What is the minimum required width of strip footing (dimension “A”) for the wall shown?
#63. The referenced standard for the determination of a listed flame-spread rating for structural lumber of Houses is:
#64. Concrete for a column must have a compressive strength, after 28 days, of not less than:
#65. In a steel storage building, a mezzanine that supports mechanical equipment at the back of the building and to which access is provided for maintenance purposes only. The height of the guard required around the mezzanine is:
#66. Doors in a Barrier-Free path of travel are required to be provided with clear wall space on the latch side of the door. Where a door swings away from the approach side, the wall space shall be;
#67. If an owner wants to build ICF foundation walls for the basement, what he needs to do?
#68. Which one of the following is not an acceptable method for supporting an assembly which required to have a fire-resistance ratings of not less than 45min?
#69. What is the minimum rating of construction sheathing subflooring applied over floor joists spaced at 610 mm o.c.? Subsection 9.30.2 does not require an underlay.
#70. A sheathing membrane that forms part of the second plane of protection for an exterior wall must comply to:
#71. For a recreational camp with an anticipated occupant load of 40 people, how many water closets are required?
#72. What is the minimum thickness of plywood subflooring applied over floor joists spaced at 610 mm o.c. when 19 mm thick hardwood strip flooring is applied over the subfloor?
#73. A new part 9 house that is designed in accordance with Compliance Package A4 in listed Table 3.1.1.2.A of SB-12. The house is located in Mekham and has 16.5% window to wall ratio. What is the permitted maximum U-value for the windows in the house?
#74. The stud wall reinforcement must allow the installation of grab bars to resist a load of:
#75. The provisions of Section 9.23 apply only to the following structures (select the most correct answer):