#1. The maximum spacing of lateral support for the 230mm loadbearing cavity wall is:
#2. Except for sliding glass partitions that separate a public corridor from an adjacent occupancy and that are open during normal working hours, transparent panels that could be mistaken as a means of egress shall be:
#3. When the foundation wall of the House is constructed as a prescribed flat ICF foundation wall, the concrete:
#4. The function of the of the second plane of protection is to:
#5. A washroom containing plumbing fixtures for restaurant employees shall be located in;
#6. What is the minimum size of pickets in accordance with Detail ED-1 in SB-7?
#7. An exterior exit door is located in an exterior wall at the main floor of a three storey office building. There is no internal enclosure to the exit stair and the main floor has a single tenancy (i.e., no public corridor). Adjacent to the exit door is a window which is 1 200 mm away from the door; this window;
#8. OSB and waferboard panels used as cladding must have all their vertical and horizontal edges supported and treated with:
#9. The minimum length of nails for the attachment of wood trim is:
#10. Wood ledger boards supporting floor joists that span 4.2 m must be anchored to flat ICF walls with:
#11. Interior wall finishes for garages;
#12. Wooden stairs used as an exit stair for a Group D occupancy span from the 1st floor to the 2nd floor. The stairs are free-standing. What is the minimum stringer size?
#13. At the intersection of masonry chimney and a shingle roof, counter flashing
#14. Tents not occupied by the public are required to be separated from each other by
#15. Granular material under slabs-on-ground is;
#16. Grab bars in water closet stalls that are required to be Barrier-Free accessible must be designed to resist the following load(s);
#17. The minimum vertical clearance from an entrance to a parking storey provided with Barrier-Free access is;
#18. According to Row 2, Column 3 of Table 9.15.3.4., the minimum width of strip footings supporting interior walls of a two storey house is 350 mm. If the House was to be constructed on gravel, sand or silt where the elevation of the water table was 450 mm below the underside of footing elevation, the width of the footing supporting an interior load- bearing partition (without masonry) would need to be a minimum of:
#19. The maximum temperature for hot water is
#20. The expansion gap between sheets of panel-type roof sheathing must:
#21. Asphalt-coated or asphalt-impregnated fibreboard conforming to CAN/ULC-S706, “Wood Fibre Thermal Insulation for Buildings”, is permitted to be used as a roof sheathing over supports spaced not more than 406 mm o.c., the fiberboard to be
#22. Concrete for a column must have a compressive strength, after 28 days, of not less than:
#23. 4. A dwelling unit that contains sleeping accommodations for not more than 2 persons contains:
#24. The minimum thickness for matched hardwood wood strip flooring applied on joists spaced at mm o/c with a plywood subfloor is;
#25. What would be the stud size, thickness and spacing for a non-loadbearing exterior wall 3 500 mm high?

#26. What is the minimum required width of strip footing (dimension “A”) for the wall shown?
#27. The minimum footing sizes of Table 9.15.3.4. are based on a maximum specified live load, on any floor supported by the footings, of:
#28. The maximum surface flame spread rating for enclosing material in a crawl space is
#29. A required guard in a Group D occupancy is required to be;
#30. if a building is built of masonry units in a earthquake area and it is determined that the total amount of reinforcing steel is to be 750 mm2, what is the minimum amount of horizontal steel in this case?
#31. The depth of chases located in 240 mm thick masonry walls are limited to
#32. According to Table 4.1.5.3., by way of Clauses 9.4.1.1.(1)(c), 9.23.4.1.(1)(a) and (b), the minimum specified uniformly distributed live load on any area of floor other than floors of bedrooms in Houses is
#33. The maximum height for a handrail on a ramp serving a Group C occupancy is
#34. Mirrored glass doors conforming to CAN/CGSB-82.6-M, “Doors, Mirrored Glass, Sliding or Folding, Wardrobe” and mirrored glass doors reinforced with a film backing that meet the impact resistance requirements specified in CAN/CGSB-12.5-M, “Mirrors, Silvered” may be used
#35. The minimum length of nails for the attachment of metal siding is:
#36. Wood frame foundation walls enclosing a crawl space must conform to
#37. As a general rule, a wall plate in a stud wall comprised of 38 mm × 64 mm studs is:
#38. Waferboard or OSB subflooring must be installed with the direction of face orientation:
#39. Combined occupancies that are prohibited include;
#40. in a Division B Part 9 house, if the space between roof joists in a cathedral ceiling with a slope of 1 in 3 are installed, the ratio of vent area to insulated ceiling area to be provided shall be not less than:
#41. As a general rule, the provisions found in Section 9.20. apply to unreinforced walls that are;
#42. Lumber roof sheathing must not be wider than
#43. A second storey window in a lounge area in a seniors' apartment building (i.e., Group C Residential and NOT Group B lnstitutional)extends to within 300 mm of the finish floor. That window is required to be
#44. A kitchen that is 7 m2 in a dwelling unit designed to accommodate more than 2 persons the minimum ceiling height of 2 300 mm must be provided over an area of not less than:
#45. A projecting sign overhangs a sidewalk; the minimum clearance to this sign is;
#46. If the minimum width of the strip footing supporting the exterior walls of the a House is at 480 mm. If the House was to be constructed on gravel, sand or silt where the elevation of the water table was 450 mm below the underside of footing elevation, the width of the footing supporting the exterior walls would need to be a minimum of:
#47. Blocking between framing members that is referenced in Sentence 9.27.5.1.(1) must not be less than:
#48. Which one of the following is NOT an acceptable method of supporting an assembly in a non-combustible construction building, and required to have a fire resistance rating of not less than 1.5 h:
#49. In a three storey Group D building, the windows located above the first storey are required to
#50. A parapet wall for a part 9 building shall
#51. The roof framing supported on the top of an ICF wall must be fixed to a top plate which is anchored to the wall with anchor bolts:
#52. A curved stair is being used as an exit serving a Group E occupancy. What is the minimum tread run exclusive the nosing?
#53. A self-service storage building has an occupant load of 50. How many water closets and lavatories are required?
#54. The maximum slope for an exterior pedestrian ramp serving a Group D occupancy is;
#55. A building has 4 pedestrian entrances. How many of those entrances must be Barrier-Free entrances?
#56. Struts used to provide intermediate support for roof framing members must be inclined by:
#57. A House occupied year-round has a basement and a single storey with cathedral ceilings attached to roof joists. It is equipped with electric baseboard heaters and has two air circulation fans hanging from cathedral ceilings. What is the minimum nominal thermal resistance of ceiling insulation if the House was constructed in Kapuskasing?
#58. If an owner wants to build ICF foundation walls for the basement, what he needs to do?
#59. A suite serves a business and personal services occupancy, has an area of 150 m2 and the distance to the nearest egress door is 30 m. How many egress doors are required?
#60. When the foundation wall of a House is constructed as a prescribed flat ICF foundation wall, the maximum spacing of horizontal reinforcement for the wall is:
#61. According to division B, Subsection 9.10.18., a janitor room:
#62. An unfinished basement has an area of 100 m2. How many lighting fixtures are required
#63. The minimum uniformly distributed live load (UDL) for Exterior balcony that serves a single dwelling unit in a House is:
#64. In a house, a bedroom door shall be NOT less than:
#65. An interior stair not serving a dwelling unit is required to have a landing(s) at the
#66. A roof, with Code complying asphalt fibreboard sheathing, may support the following type of roofing.
#67. In loadbearing flat ICF walls, what is the maximum opening that can be utilized without a lintel?:
#68. A laundry dyer exhaust duct in a division B, Part 9 house:
#69. A 0.76 mm carbon steel sheet connector is required to have corrosion-resistance which is in accordance with

#70. If the construction site has high water table issue, the width of foundation (dimension “A”) to be:
#71. An exit doorway serving more than one dwelling unit that has a pair of doors and both are active leaves, they shall be
#72. The minimum thickness of plywood cladding (face grain parallel to studs at 400 mm o.c) applied over sheathing is
#73. A building being used as a seasonal recreational building need not to comply with the following previsions as found in part 9 except for the following::
#74. What is the maximum width of lumber subflooring applied to joists at 406 mm o.c.?
#75. Slab on ground that support a roof load in a one storey part 9 building